Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 15(3): e0229206, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32134960

RESUMO

Here we describe an industry-wide collaboration aimed at assessing the binding properties of a comprehensive panel of monoclonal antibodies (mAbs) against programmed cell death protein 1 (PD-1), an important checkpoint protein in cancer immunotherapy and validated therapeutic target, with well over thirty unique mAbs either in clinical development or market-approved in the United States, the European Union or China. The binding kinetics of the PD-1/mAb interactions were measured by surface plasmon resonance (SPR) using a Carterra LSA instrument and the results were compared to data collected on a Biacore 8K. The effect of chip type on the SPR-derived binding rate constants and affinities were explored and the results compared with solution affinities from Meso Scale Discovery (MSD) and Kinetic Exclusion Assay (KinExA) experiments. When using flat chip types, the LSA and 8K platforms yielded near-identical kinetic rate and affinity constants that matched solution phase values more closely than those produced on 3D-hydrogels. Of the anti-PD-1 mAbs tested, which included a portion of those known to be in clinical development or approved, the affinities spanned from single digit picomolar to nearly 425 nM, challenging the dynamic range of our methods. The LSA instrument was also used to perform epitope binning and ligand competition studies which revealed over ten unique competitive binding profiles within this group of mAbs.


Assuntos
Anticorpos Monoclonais/farmacologia , Técnicas Biossensoriais/métodos , Receptor de Morte Celular Programada 1/imunologia , China , Desenvolvimento de Medicamentos , Epitopos/imunologia , União Europeia , Ensaios de Triagem em Larga Escala , Humanos , Receptor de Morte Celular Programada 1/química , Ligação Proteica , Ressonância de Plasmônio de Superfície , Estados Unidos
2.
Eng Rep ; 2(5): e12147, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-34901768

RESUMO

The development of therapeutic monoclonal antibodies (mAbs) can be hindered by their tendency to aggregate throughout their lifetime, which can illicit immunogenic responses and render mAb manufacturing unfeasible. Consequently, there is a need to identify mAbs with desirable thermodynamic stability, solubility, and lack of self-association. These behaviors are assessed using an array of in silico and in vitro assays, as no single assay can predict aggregation and developability. We have developed an extensional and shear flow device (EFD), which subjects proteins to defined hydrodynamic forces which mimic those experienced in bioprocessing. Here, we utilize the EFD to explore the aggregation propensity of 33 IgG1 mAbs, whose variable domains are derived from clinical antibodies. Using submilligram quantities of material per replicate, wide-ranging EFD-induced aggregation (9-81% protein in pellet) was observed for these mAbs, highlighting the EFD as a sensitive method to assess aggregation propensity. By comparing the EFD-induced aggregation data to those obtained previously from 12 other biophysical assays, we show that the EFD provides distinct information compared with current measures of adverse biophysical behavior. Assessing a candidate's liability to hydrodynamic force thus adds novel insight into the rational selection of developable mAbs that complements other assays.

3.
SLAS Technol ; 22(5): 547-556, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28430560

RESUMO

The state-of-the-art industrial drug discovery approach is the empirical interrogation of a library of drug candidates against a target molecule. The advantage of high-throughput kinetic measurements over equilibrium assessments is the ability to measure each of the kinetic components of binding affinity. Although high-throughput capabilities have improved with advances in instrument hardware, three bottlenecks in data processing remain: (1) intrinsic molecular properties that lead to poor biophysical quality in vitro are not accounted for in commercially available analysis models, (2) processing data through a user interface is time-consuming and not amenable to parallelized data collection, and (3) a commercial solution that includes historical kinetic data in the analysis of kinetic competition data does not exist. Herein, we describe a generally applicable method for the automated analysis, storage, and retrieval of kinetic binding data. This analysis can deconvolve poor quality data on-the-fly and store and organize historical data in a queryable format for use in future analyses. Such database-centric strategies afford greater insight into the molecular mechanisms of kinetic competition, allowing for the rapid identification of allosteric effectors and the presentation of kinetic competition data in absolute terms of percent bound to antigen on the biosensor.


Assuntos
Anticorpos/metabolismo , Automação Laboratorial/métodos , Processamento Eletrônico de Dados/métodos , Ensaios de Triagem em Larga Escala/métodos , Animais , Humanos , Cinética , Ligação Proteica
4.
MAbs ; 9(4): 646-653, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28281887

RESUMO

Susceptibility of methionine to oxidation is an important concern for chemical stability during the development of a monoclonal antibody (mAb) therapeutic. To minimize downstream risks, leading candidates are usually screened under forced oxidation conditions to identify oxidation-labile molecules. Here we report results of forced oxidation on a large set of in-house expressed and purified mAbs with variable region sequences corresponding to 121 clinical stage mAbs. These mAb samples were treated with 0.1% H2O2 for 24 hours before enzymatic cleavage below the hinge, followed by reduction of inter-chain disulfide bonds for the detection of the light chain, Fab portion of heavy chain (Fd) and Fc by liquid chromatography-mass spectrometry. This high-throughput, middle-down approach allows detection of oxidation site(s) at the resolution of 3 distinct segments. The experimental oxidation data correlates well with theoretical predictions based on the solvent-accessible surface area of the methionine side-chains within these segments. These results validate the use of upstream computational modeling to predict mAb oxidation susceptibility at the sequence level.


Assuntos
Anticorpos Monoclonais/química , Peróxido de Hidrogênio/química , Espectrometria de Massas/métodos , Metionina/química , Modelos Moleculares , Cromatografia Líquida/métodos , Células HEK293 , Humanos , Oxirredução
5.
Proc Natl Acad Sci U S A ; 114(5): 944-949, 2017 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-28096333

RESUMO

Antibodies are a highly successful class of biological drugs, with over 50 such molecules approved for therapeutic use and hundreds more currently in clinical development. Improvements in technology for the discovery and optimization of high-potency antibodies have greatly increased the chances for finding binding molecules with desired biological properties; however, achieving drug-like properties at the same time is an additional requirement that is receiving increased attention. In this work, we attempt to quantify the historical limits of acceptability for multiple biophysical metrics of "developability." Amino acid sequences from 137 antibodies in advanced clinical stages, including 48 approved for therapeutic use, were collected and used to construct isotype-matched IgG1 antibodies, which were then expressed in mammalian cells. The resulting material for each source antibody was evaluated in a dozen biophysical property assays. The distributions of the observed metrics are used to empirically define boundaries of drug-like behavior that can represent practical guidelines for future antibody drug candidates.


Assuntos
Anticorpos Monoclonais , Descoberta de Drogas/métodos , Sequência de Aminoácidos , Anticorpos Monoclonais/química , Fenômenos Biofísicos , Aprovação de Drogas , Células HEK293 , Humanos , Imunoglobulina G/química
6.
MAbs ; 8(7): 1269-1275, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27610650

RESUMO

The importance of the neonatal Fc receptor (FcRn) in extending the serum half-life of monoclonal antibodies (mAbs) is well demonstrated, and has led to the development of multiple engineering approaches designed to alter Fc interactions with FcRn. Recent reports have additionally highlighted the effect of nonspecific interactions on antibody pharmacokinetics (PK), suggesting an FcRn-independent mechanism for mAb clearance. In this report we examine a case study of 2 anti-interleukin-12/23 antibodies, ustekinumab and briakinumab, which share the same target and Fc, but differ in variable region sequences. Ustekinumab displayed near baseline signal in a wide range of early stage developability assays for undesirable protein/protein interactions, while briakinumab showed significant propensity for self- and cross-interactions. This phenotypic difference correlates with faster clearance rates for briakinumab in both human FcRn transgenic and FcRn knockout mice. These findings support a dominant contribution for FcRn-independent clearance for antibodies with high nonspecificity, and highlight a key role for early stage developability screening to eliminate clones with such high nonspecific disposition PK.


Assuntos
Anticorpos Monoclonais/farmacocinética , Afinidade de Anticorpos/imunologia , Antígenos de Histocompatibilidade Classe I/imunologia , Receptores Fc/imunologia , Ustekinumab/farmacocinética , Animais , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais Humanizados , Ensaio de Imunoadsorção Enzimática , Humanos , Região Variável de Imunoglobulina/imunologia , Camundongos , Ustekinumab/imunologia
7.
J Biomol Screen ; 21(1): 88-95, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26442912

RESUMO

Real-time and label-free antibody screening systems are becoming more popular because of the increasing output of purified antibodies and antibody supernatant from many antibody discovery platforms. However, the properties of the biosensor can greatly affect the kinetic and epitope binning results generated by these label-free screening systems. ForteBio human-specific ProA, anti-human IgG quantitation (AHQ), anti-human Fc capture (AHC) sensors, and custom biotinylated-anti-human Fc capture (b-AHFc) sensors were evaluated in terms of loading ability, regeneration, kinetic characterization, and epitope binning with both purified IgG and IgG supernatant. AHC sensors proved unreliable for kinetic or binning assays at times, whereas AHQ sensors showed poor loading and regeneration abilities. ProA sensors worked well with both purified IgG and IgG supernatant. However, the interaction between ProA sensors and the Fab region of the IgG with VH3 germline limited the application of ProA sensors, especially in the epitope binning experiment. In an attempt to generate a biosensor type that would be compatible with a variety of germlines and sample types, we found that the custom b-AHFc sensors appeared to be robust working with both purified IgG and IgG supernatant, with little evidence of sensor-related artifacts.


Assuntos
Anticorpos Monoclonais/imunologia , Bioensaio/instrumentação , Bioensaio/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Epitopos/imunologia , Leveduras/imunologia , Biotinilação/métodos , Humanos , Imunoglobulina G/imunologia , Cinética
8.
MAbs ; 7(4): 770-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26047159

RESUMO

Although improvements in technology for the isolation of potential therapeutic antibodies have made the process increasingly predictable, the development of biologically active monoclonal antibodies (mAbs) into drugs can often be impeded by developability issues such as poor expression, solubility, and promiscuous cross-reactivity. Establishing early stage developability screening assays capable of predicting late stage behavior is therefore of high value to minimize development risks. Toward this goal, we selected a panel of 16 monoclonal antibodies (mAbs) representing different developability profiles, in terms of self- and cross-interaction propensity, and examined their downstream behavior from expression titer to accelerated stability and pharmacokinetics in mice. Clearance rates showed significant rank-order correlations to 2 cross-interaction related assays, with the closest correlation to a non-specificity assay on the surface of yeast. Additionally, 2 self-association assays correlated with each other but not to mouse clearance rate. This case study suggests that combining assays capable of high throughput screening of self- and cross-interaction early in the discovery stage could significantly lower downstream development risks.


Assuntos
Anticorpos Monoclonais/farmacologia , Anticorpos Monoclonais/farmacocinética , Imunoglobulina G/farmacologia , Animais , Anticorpos Monoclonais/imunologia , Reações Cruzadas , Humanos , Imunoglobulina G/imunologia , Camundongos , Estabilidade Proteica
9.
MAbs ; 7(3): 553-61, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25790175

RESUMO

The effectiveness of therapeutic monoclonal antibodies (mAbs) is governed not only by their bioactivity, but also by their biophysical properties. Assays for rapidly evaluating the biophysical properties of mAbs are valuable for identifying those most likely to exhibit superior properties such as high solubility, low viscosity and slow serum clearance. Analytical hydrophobic interaction chromatography (HIC), which is performed at high salt concentrations to enhance hydrophobic interactions, is an attractive assay for identifying mAbs with low hydrophobicity. However, this assay is low throughput and thus not amenable to processing the large numbers of mAbs that are commonly generated during antibody discovery. Therefore, we investigated whether an alternative, higher throughput, assay could be developed that is based on evaluating antibody self-association at high salt concentrations using affinity-capture self-interaction nanoparticle spectroscopy (AC-SINS). Our approach is to coat gold nanoparticles with polyclonal anti-human antibodies, use these conjugates to immobilize human mAbs, and evaluate mAb self-interactions by measuring the plasmon wavelengths of the antibody conjugates as a function of ammonium sulfate concentration. We find that hydrophobic mAbs, as identified by HIC, generally show significant self-association at low to moderate ammonium sulfate concentrations, while hydrophilic mAbs typically show self-association only at high ammonium sulfate concentrations. The correlation between AC-SINS and HIC measurements suggests that our assay, which can evaluate tens to hundreds of mAbs in a parallel manner and requires only small (microgram) amounts of antibody, will enable early identification of mAb candidates with low hydrophobicity and improved biophysical properties.


Assuntos
Anticorpos Monoclonais/química , Ouro/química , Nanopartículas Metálicas/química , Cromatografia Líquida , Células HEK293 , Humanos , Interações Hidrofóbicas e Hidrofílicas , Solubilidade , Análise Espectral
10.
MAbs ; 6(2): 483-92, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24492294

RESUMO

The discovery of monoclonal antibodies (mAbs) that bind to a particular molecular target is now regarded a routine exercise. However, the successful development of mAbs that (1) express well, (2) elicit a desirable biological effect upon binding, and (3) remain soluble and display low viscosity at high concentrations is often far more challenging. Therefore, high throughput screening assays that assess self-association and aggregation early in the selection process are likely to yield mAbs with superior biophysical properties. Here, we report an improved version of affinity-capture self-interaction nanoparticle spectroscopy (AC-SINS) that is capable of screening large panels of antibodies for their propensity to self-associate. AC-SINS is based on concentrating mAbs from dilute solutions around gold nanoparticles pre-coated with polyclonal capture (e.g., anti-Fc) antibodies. Interactions between immobilized mAbs lead to reduced inter-particle distances and increased plasmon wavelengths (wavelengths of maximum absorbance), which can be readily measured by optical means. This method is attractive because it is compatible with dilute and unpurified mAb solutions that are typical during early antibody discovery. In addition, we have improved multiple aspects of this assay for increased throughput and reproducibility. A data set comprising over 400 mAbs suggests that our modified assay yields self-interaction measurements that are well-correlated with other lower throughput assays such as cross-interaction chromatography. We expect that the simplicity and throughput of our improved AC-SINS method will lead to improved selection of mAbs with excellent biophysical properties during early antibody discovery.


Assuntos
Anticorpos Imobilizados/metabolismo , Anticorpos Monoclonais/metabolismo , Ensaios de Triagem em Larga Escala/métodos , Imunoterapia/métodos , Análise Espectral/métodos , Anticorpos Monoclonais/uso terapêutico , Afinidade de Anticorpos , Células Cultivadas , Descoberta de Drogas , Ouro/química , Humanos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/estatística & dados numéricos , Multimerização Proteica , Reprodutibilidade dos Testes , Ressonância de Plasmônio de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...